RenewAire ERV/HRV & DOAS Repair in NYC
AM Profs Inc diagnoses and repairs RenewAire static-plate ERV/HRV systems and Dedicated Outdoor Air Systems (DOAS) across New York City apartment buildings meeting fresh air code requirements. If the washable core needs cleaning or airflow has dropped, we start from the actual fault.
24/7 urgent repair is available for RenewAire ventilation systems, including weekends and holidays.
Covered Equipment
Static-plate ERV/HRV units (EV, BR series)
Dedicated Outdoor Air Systems (DOAS)
Washable static-core heat exchangers
Low-voltage fan speed and damper controls
RenewAire units are commonly used for apartment ventilation and Dedicated Outdoor Air Systems in NYC buildings meeting fresh air code requirements.
Quick Answer
What is the most common RenewAire repair issue in NYC?
The primary service need in dense urban environments like NYC is regularly washing the core and replacing filters, since particulate accumulation is heavy and RenewAire's cores are specifically designed to be washable rather than disposable — skipping this maintenance is the most common cause of reduced airflow.
Last updated: July 2026
Why RenewAire Repairs Need Brand-Specific Service
RenewAire is widely recognized for being one of the earliest and most prominent manufacturers to use a static-plate heat exchanger rather than a rotating enthalpy wheel, reducing moving parts and maintenance needs — a real design distinction in the ERV/HRV category.
The company was founded in 1978, established to pioneer static-plate energy recovery ventilation technology, with its first commercial static-plate ERV core launch in 1983. Broan-NuTone LLC acquired RenewAire in 2019 and owns the brand today.
What Makes The Brand Different
Washable cores need regular attention, not replacement
Because RenewAire's static-plate cores are designed to be washable rather than disposable, the primary maintenance path is regular washing and filter replacement rather than swapping in a new core — a real cost advantage over time if maintained properly.
RenewAire units like the EV and BR series are commonly specified for Dedicated Outdoor Air Systems (DOAS) in NYC apartment buildings, delivering fresh air to meet code requirements independent of the building's heating and cooling systems.
RenewAire Systems We Service
Common symptoms, likely causes, what we check first, and when to call for each system type.
Static-Plate ERV/HRV Unit
Common symptoms: Reduced airflow, reduced energy recovery efficiency, or unusual fan noise.
Likely causes: Core fouling from particulate buildup, filter clogging, or fan/motor wear.
What we check first: Core cleanliness, filter condition, and fan operation.
What work is done: Core washing, filter replacement, and fan/motor service.
When to call: If airflow or fresh air delivery has noticeably dropped.
Frequently Asked Questions
Can a RenewAire core really be washed instead of replaced?
Yes — RenewAire's static-plate cores are specifically designed to be washable, which is a real maintenance and cost advantage over disposable-core designs, as long as washing happens regularly.
What is a Dedicated Outdoor Air System (DOAS)?
It's a ventilation system that delivers fresh outdoor air to meet code requirements independent of a building's heating and cooling systems — RenewAire units are commonly used this way in NYC apartment buildings.
When was RenewAire actually founded?
In 1978, with the company's first commercial static-plate ERV core launching in 1983 — the two dates are sometimes conflated, but they mark different milestones.
Who owns RenewAire today?
Broan-NuTone LLC, which acquired RenewAire in 2019.
What areas of NYC do you cover for RenewAire repair?
We schedule RenewAire repair across Manhattan, Brooklyn, Queens, and the Bronx.